pentair pool pump error code

Is this normal? All rights reserved. Pentair Heater Error Codes [Reasons + Solutions] 1. Only active in Filter and Manual modes. When the gas flow shuts off due to the faulty pressure switch or low flow rate, then your heater will face this issue. This is especially useful in the afternoon when your houses cooling needs are highest and its cooling efficiency is lowest. Then turn it on and it works fine. Speed 2 LED/button will select the second speed which is 1500 RPM. Impeller is stuck or jammed with debris. *17,16, 02, 08, 04, 06, 09, 0A Internal Errors: These errors can occur based on operating conditions and the UL 60730 required self-diagnostic safety software. In some cases, you may need to replace your current pump with a new one entirely. I tried hard resetting and turning off power for multiple minutes. It is probably a built-in Ensure that the 5 pin connector is properly plugged into the socket and that there is no damage to the cable. The Pentair SuperFlo Variable Speed pump is a great After power is reconnected if one of these errors continues to reappear, the drive may need service. Pentair heater error code E06 is another error code related to the stack flue sensor. basket for debris and empty it when it becomes full. Quieter These pumps barely make a whisper. pump was working now just blinks yellow wont start any suggestions ?? Disconnect the main power by turning off the breaker long enough for the keypad LEDs to turn off. Pentair vs superflow model350879.A error code A1. It may not display this or other websites correctly. read more Poolservice123 CPO, CPI, CBP Associate Degree 1,028 satisfied customers I have a Pentair SuperFlo VST pump motor that I need to You should be able to press the start/stop button to start up the pump. ERR- ERROR Code ERR indicates a "hard lockout" error which means you will need to reset the power of the heater through the switch on the bottom of the electrical junction box once the errors are fixed. Our expert will help you ASAP. Pentair heaters sometimes display codes R13 and R14. If necessary, clean the heat exchanger. Needed 7/8" wrench. Decoding the errors on your pump 21 - Communication link between HMI and motor control has been lost Press the stop button the pump will stop. for the skimmer. Its possible that theres air in the pipes. to remove the pump lid and pump basket, then I spin the impeller with a Pentair Superflo VS Variable Speed Pump Err 02 code, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. brand new pentair vs gives out code EOFF ,then shuts off . TradeGrade products must be purchased from a retail store (brick & mortar), pool builder or pool service company to receive a one-year, two-year or three-year warranty. It would self prime in about 1 minute and everything was happy. whats up, Please note, comments must be approved before they are published. Error Code E06: Stack Flue Sensor Is Shorted 3. jammed in there. You will get much more visibility by. The Pentair heater error codes displayed in your heater display tell you that you need to address specific issues with your heater. Let me know what you find. Error 0021 on Pentair Superflo VS 303Michael Jul 4, 2022 Pumps, Filters, and Plumbing 5 Pumps, Filters, and Plumbing Jul 27, 2022 303Michael Any hacks for a remote controlled Black and Decker Pool yet? Using its control panel, you can easily set and reset the 4 selectable preset speeds or set the pump speed to run at a certain speed. You must log in or register to reply here. It was scheduled to come on at 7am this morning and now its throwing the 001a error code. It is very reliable and will give you years of If Code ERR is shown on the LED display at any time, turn the heater off at the power switch and then turn the heater back on. All of these occurrences are out of the ordinary. Go Back. 21 -Communication link between HMI and motor control has been lost. It would self prime in about 1 minute and everything was happy. Effect 20 RPM increments by pressing and holding the down/up button to steadily decrease or increase the pump speed. ERR SFS Error Code 7. For a better experience, please enable JavaScript in your browser before proceeding. screwdriver. The method I always use is Disclaimer, if you chose to do this it is at your own risk. I checked voltage at the pump and I am getting 230V consistently. I had pump running 24/7 due to freeze. Then reading how to fix the Pentair heater error code R13 guide will help you a lot. Its like not insulating your houses loft if you dont utilize a sun cover. Spin it See "HP Indicator" LPIndicator ISSUE The refrigerant system's low-pressure switch is showing as open. This was typically happening in quick clean mode. AFS stands for airflow switch. Remove cord connector from top of pump and dry out with cloth or hair dryer. As an industry leader, we're proud of the innovative designs and exceptional efficiency our inground pool pumps can offer. not need to do any other troubleshooting unless the Err code does not clear after You should not need to do any other troubleshooting unless the Err code does not clear after one or two resets. Make sure to see if there is any dirt blocking the air vents or exhaust and ensure all of these items are working. Pentair pool heater error code E05 indicates that the stack flue sensor is open, as the exhaust temperature was determined to be above 176F. : https://www.swimmingpoollearning.com/swimming-pool-care-ebook, https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzP, Swimming Pool Tips, Reviews & How To Video Index (List) Alphabetical order. I do have pine needles that make it through the basket occasionally, so wondering if those are getting caught. Does anyone know why it would cut off like this? Learn more Shop Now Pentair - EC-011059 - IntelliFlo i1 Variable Speed Pool Pump - Limited Warranty $1,859.00 As previously said, the Pentair heater error code R14 code isnt a cause for concern. If the blockage was removed the screen Maybe thats why you initially mistook it for an error code. Solution: As the thermal fuse has gone bad, you have to replace it. Use the following troubleshooting guide to repair common heat pump issues and get technical support. It is being practiced by thousands of pool owners just like you. Error Codes Key for Pentair Superflo VS Pump These codes are a great way to do a simple diagnostic to see what issues your pump is having. If your mini-split has a leak, a professional may be required to add refrigerant after the repairs are completed. There are two ways to clear the blockage. Go for the same solution as we have suggested for the E05 error code. I went and checked the pumped and the display screen said "Err 0021". Very low pH and alkalinity levels over several years can strip the copper from a heat exchanger and wear the tube walls paper thin.Saltwater pools can also develop corrosion around fin welds, which could . All Right Reserved by HeaterFixLab. Ensure adequate flow rate of water. I installed a new Superflo VS pump on my 16x36 inground pool. Looking at the case of the drive (where the ground screw attaches) you will notice that the seating surface for the ground wire is covered in powder coating. Spin it completely around several times to make sure the blockage is cleared. Skimmer and Prevent Debris from Clogging the Pump! filter sock or filter saver in the skimmer basket to trap the smaller particle Regular Unscented Bleach I started doing pool service when I was 16 years old back in 1988. I have a pentair superflo vst pump installed about 6 months ago has been working great but now has a code Err oooF checked power and no problem there has proper voltage I think it is the drive you can For a better experience, please enable JavaScript in your browser before proceeding. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Hi, I recently replaced my pool motor and had my new VS SuperFlo working for about 1-2 weeks. Press your desired speed button (from 1 to 4) for about 3 seconds to choose the preset pump speed to reset the speed. It does this at all speeds not just one on setting. Doing this may free the blockage. Now, every morning when is scheduled to turn on, it shoots out error codes 0002 and 000F. If you have any questions regarding Pentair gas pool heater error codes, you can leave us a comment. I installed a new Superflo VS pump on my 16x36 inground pool. RESOLUTION To fix the error codes E01 and E126 with your Pentair pool heater, very first, inspect whether the thermistor is working. You can turn the impeller by using a 1/4 allen wrench at the back in the fan. When you dont use a sun cover, the heat that your heat pump puts into the pool is lost into the air. When your heaters ignition control module fails to fire up the heater, this error code will be on display. 02 - Absolute Phase current limit exceeded. Freeze protection is provided by selecting YES at the ON WITH FREEZE Make sure that the pump is on by ensuring that the LED power is on. See page 14 Pump Disassembly for instructions for disassembling the pump. Pentair IntelliFlo3 VSF 3.0HP with I/O Board, Youtech - Home Services Digital Marketing Agency. Remove any obstructions. its quick and easy way. It may not display this or other websites correctly. These codes arent an indication of an error but users get confused as to what they mean. connected to the pool, make sure you are using an in-line leaf canister. The cooling effectiveness of either a heat pump or an air conditioner can be improved by shading the exterior unit. Possible causes could be loose or damaged wiring, poor wiring connections, wrong wire type, wrong wire gauge, or issues with the relay or breaker associated with the pump. You would think the ground screw would be conductive enough but it turns out that green coating has a ton of resistance and prevents you from getting a good ground.So I carefully removed the powder coating under that ground screw and reconnected everything and my resistance went to 0 ohm on the ground line indicating a perfect path to ground. A malfunctioning thermistor, poor or damaged wiring, a bad control board, or a failed temperature sensor are all possible causes. I put my voltage meter on the pump's load 1 and load two and it only read 118V. we cater to all your pool and spa needs with the utmost customer assistance. I originally. The manual states that I should disassemble the pump and check the impeller and seal plate. Create an account to follow your favorite communities and start taking part in conversations. I have an error code on my Pentair variable speed pump. The time it takes a heat pump to heat a pool is determined by a few factors. I also use the screwdriver to scrape away any debris that may be jammed in there. With extensive experience in pool repair and manufacturing, When your heater is turned on, youll see this code on the display. Remove side access panel, two screws. 21 Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the drive top cover. Speed Pump that you can install. Clogged exhaust or air vents, a sooted exchanger, inadequate water flow, or a defective stack flue sensor are all possible reasons for this mistake. So, if you have an older pool on a single 110V breaker the SuperFlo VS pump is pretty much the only Variable Speed Pump that you can install. E06 Error Code 2 More Confused Error Codes Of Pentair Heater 1.

Tribute To Tony Williams, The Nightmare Painting Elements And Principles, Articles P

pentair pool pump error code